



Need a full custom project? See the options below.
Need a full custom project? See the options below.
Study how a single-bolt connection transfers load between stamped tube ends in a double-layer steel space truss. This Abaqus package is designed for structural engineers, researchers and analysts who want to inspect the local shell stresses while retaining the full beam model of the truss.

The model uses S4 shell elements for the eight stamped tube ends at the upper central node and B31 beam elements for the remaining members and support columns. Kinematic couplings transfer forces through the shell-to-beam interfaces. The stamped overlap is idealized by equal translations within the coupled footprint.
The grid pitch is 2,500 mm and the truss depth is 1,500 mm. The four corner column bases are fixed. Four equal downward loads of 40 kN are applied at the central lower nodes in a geometrically nonlinear static step.



The nominal upper-chord stress is σ = N/A, where N is the signed axial force in newtons and A = 465 mm2 is the reported gross section area. The strain reference is the published ideal-truss curve. The compressive shell peak is the minimum across both shell faces.
| Quantity | Published | Abaqus | Unit |
|---|---|---|---|
| Upper-chord compression | 31.0 | 29.2 | kN |
| Nominal chord stress | -66.7 | -62.8 | MPa |
| Support-diagonal compression strain | 650.8 | 645.1 | µε |
| Peak compressive global X shell stress | -216.1 | -205.1 | MPa |



Run the model in your own licensed Abaqus/Standard and Abaqus/CAE installation. The optional comparison charts use Matplotlib.
Vendrame, A. M., and Gonçalves, R. M. (2002). “Análise numérica e experimental de estruturas espaciais constituídas de barras de extremidades estampadas: estudo dos nós.” Cadernos de Engenharia de Estruturas, no. 20, pp. 75–103, EESC-USP. Reference paper.
The study examines how the typical overlapping stamped-end joint behaves in a space truss. The authors used shell elements around the tube ends and compared numerical responses with experimental evidence from a flat truss prototype. The Abaqus package focuses on the center-joint benchmark in Figures 19 and 33.
Yes. Open the supplied CAE file. Export any changes to the input deck before rerunning the script.
It writes the load history, a benchmark table and stress images for the solved case.
See the separate Ansys stamped-end tube joint model.
Need more than the files?
There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.
We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.
Other packages engineers working on this topic also download.
Extended End-Plate Moment Connection in Abaqus: Bolted Beam-to-Column Joint, after Rahchamandi et al. (2026)€129,00
Bolt Preload Abaqus: SC3 End-Plate Connection with All-Hex Bolts (Native Bolt Load and Initial Stress, .inp and .cae)€89,00
Bolt Pretension in Ansys Workbench: SC3 End-Plate Connection with All-Hex Bolts (Pretension Section with Lock, Initial Shank Stress, .wbpz)€89,00
DNV-RP-C208 Example 8.9 in ANSYS: Low-Cycle Fatigue of a Tubular T-Joint under Out-of-Plane Load€29,00
DNV-RP-C208 Example 8.9 in Abaqus: Low-Cycle Fatigue of a Tubular T-Joint under Out-of-Plane Load€29,00Need a full custom project? See the options below.

€119,00
See more
Want to receive push notifications for all major on-site activities?