Ansys Bolted Connection Bundle | Chen T1 and SC3

€59,00
Optional extras

Need a full custom project? See the options below.

€59,00
Optional extras

Need a full custom project? See the options below.

19 people watching this product now!

Material Includes

  • Chen T1 Workbench archive, solver input and native contour
  • Chen T1 PDF workshop
  • SC3 Workbench archive, native contour, results summary and README

Audience

  • Structural engineers, FEA analysts and engineering students

What You Will Learn?

  • Set up bolt pretension and lock
  • Study flange opening under eccentric tension
  • Compare two SC3 pretension methods under bending
  • Read force–opening and moment–rotation curves

About Course

Get two complete Ansys projects in one purchase. Use Chen T1 to study flange opening under eccentric tension, then use SC3 to compare bolt load and lock with initial shank stress in an extended end-plate beam-to-column connection. Each case has its own Workbench archive and result material.

Watch the bolted joints open in Ansys

  • Chen T1 rib-stiffened bolted flange. Workbench archive, solver input, native result image and PDF workshop.
  • SC3 bolt pretension. Workbench archive with both pretension methods, native Ansys result image, PDF results summary and README.

Chen T1 rib-stiffened bolted flange

Follow the pretension and lock steps for the two rings of M20 bolts, then inspect the response to a 9 mm pull applied at 29.5 mm eccentricity.

Ansys assembly and deformed flange under load
Ansys geometry and a deformed view of the central flange from the eccentric-tension step.

Geometry, mesh and loading

The symmetry model preserves the two bolt circles, the flange ribs and the tube and flange geometry. The mesh uses 99,680 eight-node SOLID185 solids. Structured sectors resolve the bolt-hole and bearing regions, and contact allows the central flange to open. Each full bolt receives 10.053 kN of pretension. The second step locks the attained bolt adjustment before the upper grip moves. For an applied tensile force F in kN, the eccentric loading moment is M = F e in kN·mm, with eccentricity e = 29.5 mm.

Structured hexahedral mesh of the Ansys T1 half specimen
Structured hex mesh for the symmetry model. The adjacent native detail identifies the central flange, rib and bearing regions.

Benchmarked results

The Ansys model completed the 9 mm stroke. The computed peak was 2,350.4 kN at 5.35 mm flange opening. Chen et al. reported 2,421 kN in the test and 2,431 kN in their numerical model. The computed peak was 2.92% and 3.31% lower, respectively. The mean absolute load difference from the published numerical curve was 9.62% over 0.25–5.00 mm of mean flange opening. Peak-load agreement applies to that individual response quantity.

T1 tensile load versus D1 and D10 flange opening
Computed tensile force versus mean D1/D10 flange opening compared with the numerical trace from Chen et al., Fig. 11a.

FEA model results and experiment views

Native Ansys von Mises stress result at 2,260.8 kN
Native Ansys equivalent-stress contour in MPa at 2,260.8 kN of applied tension. Deformation scale is 1×.
Chen T1 experiment and Ansys flange stress detail
Reference experiment and native Ansys flange close-up under load. Photograph cropped from Chen, Mou, Guo, Wang and Xue (2022), Fig. 14a. Source article · CC BY 4.0.
End-on views of Chen T1 post-test bolts and loaded Ansys bolts
The reference photograph shows removed bolts after testing. The Ansys end-on image shows bolt displacement magnitude while the half specimen is loaded. This training model covers pretension, contact and opening. Bolt fracture and residual deformation are outside its validated scope. Photograph cropped from Chen, Mou, Guo, Wang and Xue (2022), Fig. 14a. Source article · CC BY 4.0.
SBO1 bolt section force from the Ansys model
Computed outer-bolt SBO1 axial section force versus specimen tensile force on the rising branch.
Ansys flange rim opening profiles at three loads
Computed flange opening profiles at 700, 1,500 and 2,052 kN of specimen tensile force.

SC3 bolt pretension and end-plate rotation

SC3 models a bolted extended end-plate connection under monotonic bending. Compare a bolt pretension section with the attained adjustment locked against an initial axial stress applied to the bolt shank. The model uses hexahedral solid elements, including the bolts. Derive the joint moment as the full actuator force times the 1.2 m lever arm.

Unedited Ansys Mechanical von Mises stress contour of the SC3 end-plate joint with pretensioned hexahedral bolts
Native Ansys Mechanical equivalent-stress contour for the SC3 extended end-plate connection.
Ansys close-up of the all-hexahedral brick-element mesh of the pretensioned bolts
The structured hexahedral mesh through the bolt head, shank and nut.

At 0.067 rad, the all-hexahedral Ansys models give 300.7 kN·m for bolt load and lock and 300.4 kN·m for initial shank stress. The SC3 test reported 308.3 kN·m at the same rotation. This comparison covers the pre-fracture bending response.

Ansys moment-rotation comparison for the SC3 extended end-plate connection
Moment–rotation comparison for the two SC3 preload methods, with the reference results.

Krolo, P., Grandić, D. and Bulić, M. (2016). The Guidelines for Modelling the Preloading Bolts in the Structural Connection Using Finite Element Methods. The authors compared two ways of introducing bolt preload, discussed contact and convergence in the numerical models, and compared the extended end-plate moment–rotation response with a monotonic test. Source paper. SC3 standalone product.

Course Content

Chen T1 PDF workshop

  1. Open the Workbench model
  2. Inspect contact, pretension and the eccentric fixtures
  3. Run the model and extract opening and bolt force
  4. Interpret the benchmark and deformation plots

SC3 PDF results summary

Compare the two bolt-preload analyses and review the moment at 0.067 rad against the SC3 reference test.

Chen T1 reference paper

Chen, Y., Mou, W., Guo, Y., Wang, J. and Xue, B. (2022). Experimental /numerical study of a circular rib-stiffened flange connection with inner and outer flange plates under combined bending and tensile loading. Scientific Reports 12, 8823. DOI 10.1038/s41598-022-12896-w.

The authors combined tests, numerical analysis and a sectional calculation to study how eccentricity affects the tensile and bending resistance of circular flanges with inner and outer bolt rings. They examined flange opening, bolt force, failure and the interaction between bending and tension. For specimens with sufficiently strong ribs, welds and flange plates, bolt strength governed the ultimate resistance.

See the Abaqus edition of the Chen T1 study.

Need more than the files?

There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.

We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.

Course Content

Product Files

  • Chen T1 Ansys model files
  • Chen T1 PDF workshop
  • SC3 Ansys package

Reviews

No Review Yet
No Review Yet
€59,00
Optional extras

Need a full custom project? See the options below.

19 people watching this product now!

Material Includes

  • Chen T1 Workbench archive, solver input and native contour
  • Chen T1 PDF workshop
  • SC3 Workbench archive, native contour, results summary and README

Audience

  • Structural engineers, FEA analysts and engineering students

Related  Products

See more

Want to receive push notifications for all major on-site activities?

✕