Get two complete Ansys projects in one purchase. Use Chen T1 to study flange opening under eccentric tension, then use SC3 to compare bolt load and lock with initial shank stress in an extended end-plate beam-to-column connection. Each case has its own Workbench archive and result material.
Follow the pretension and lock steps for the two rings of M20 bolts, then inspect the response to a 9 mm pull applied at 29.5 mm eccentricity.

The symmetry model preserves the two bolt circles, the flange ribs and the tube and flange geometry. The mesh uses 99,680 eight-node SOLID185 solids. Structured sectors resolve the bolt-hole and bearing regions, and contact allows the central flange to open. Each full bolt receives 10.053 kN of pretension. The second step locks the attained bolt adjustment before the upper grip moves. For an applied tensile force F in kN, the eccentric loading moment is M = F e in kN·mm, with eccentricity e = 29.5 mm.

The Ansys model completed the 9 mm stroke. The computed peak was 2,350.4 kN at 5.35 mm flange opening. Chen et al. reported 2,421 kN in the test and 2,431 kN in their numerical model. The computed peak was 2.92% and 3.31% lower, respectively. The mean absolute load difference from the published numerical curve was 9.62% over 0.25–5.00 mm of mean flange opening. Peak-load agreement applies to that individual response quantity.






SC3 models a bolted extended end-plate connection under monotonic bending. Compare a bolt pretension section with the attained adjustment locked against an initial axial stress applied to the bolt shank. The model uses hexahedral solid elements, including the bolts. Derive the joint moment as the full actuator force times the 1.2 m lever arm.


At 0.067 rad, the all-hexahedral Ansys models give 300.7 kN·m for bolt load and lock and 300.4 kN·m for initial shank stress. The SC3 test reported 308.3 kN·m at the same rotation. This comparison covers the pre-fracture bending response.

Krolo, P., Grandić, D. and Bulić, M. (2016). The Guidelines for Modelling the Preloading Bolts in the Structural Connection Using Finite Element Methods. The authors compared two ways of introducing bolt preload, discussed contact and convergence in the numerical models, and compared the extended end-plate moment–rotation response with a monotonic test. Source paper. SC3 standalone product.
Compare the two bolt-preload analyses and review the moment at 0.067 rad against the SC3 reference test.
Chen, Y., Mou, W., Guo, Y., Wang, J. and Xue, B. (2022). Experimental /numerical study of a circular rib-stiffened flange connection with inner and outer flange plates under combined bending and tensile loading. Scientific Reports 12, 8823. DOI 10.1038/s41598-022-12896-w.
The authors combined tests, numerical analysis and a sectional calculation to study how eccentricity affects the tensile and bending resistance of circular flanges with inner and outer bolt rings. They examined flange opening, bolt force, failure and the interaction between bending and tension. For specimens with sufficiently strong ribs, welds and flange plates, bolt strength governed the ultimate resistance.
Need more than the files?
There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.
We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.
Other packages engineers working on this topic also download.
Bolt Pretension in Ansys Workbench: SC3 End-Plate Connection with All-Hex Bolts (Pretension Section with Lock, Initial Shank Stress, .wbpz)€89,00
Dynamic analysis of the three-point bending test of a bolted steel splice connection
Timber–Steel Composite Beam Under Air Blast in Abaqus: CONWEP, Hashin & Johnson–Cook Damage
Four-Point Bending of a Bolted Timber–Steel Composite Beam in Abaqus: Hill Plasticity & Force–Displacement
Bolt Preload Abaqus: SC3 End-Plate Connection with All-Hex Bolts (Native Bolt Load and Initial Stress, .inp and .cae)€89,00
Behaviour analysis of demountable tubular column-to-base plate joints with studsNeed a full custom project? See the options below.
See more
Want to receive push notifications for all major on-site activities?