Compare eigenvalue buckling in a thin-walled aluminum silo under two design load combinations: wind and suction on an empty silo, and seismic loading on a filled silo. The exercise includes a verified Ansys Workbench archive and a PDF tutorial.
The model uses first-order shell elements and four pinned bearing patches. Ansys solves the static preload and then the eigenproblem (K + λKσ)φ = 0. K is the elastic stiffness, Kσ is the preload-dependent geometric stiffness, and λ scales the reference load combination.

For LK39, Ansys gives a first positive buckling factor of 3.433 versus 3.56 in the thesis (−3.57%). The mode concentrates in the upper shell. For LK50, Ansys gives 4.059 versus 4.26 (−4.72%), with the mode concentrated in the lower skirt.



Alexander Köll, Bemessung eines Aluminiumsilos nach Eurocode unter Berücksichtigung des Lastfalls Staubexplosion, master’s thesis, University of Innsbruck, 2021, sec. 3.3 and Figs. 3.39–3.40. The thesis studies bulk storage, environmental actions and prescribed internal pressure in an aluminum silo. This exercise covers two of its linear buckling comparisons.
Need more than the files?
There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.
We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.
Other packages engineers working on this topic also download.
Optimization in ANSYS: Learn Design Optimization
ANSYS Mechanical Tutorial for Beginners to Intermediate UsersNeed a full custom project? See the options below.

€119,00
See more
Want to receive push notifications for all major on-site activities?